Type |
Power
kW*
|
|
|
|
|
|
|
|
|
ACU401
- 01 |
0,25
|
|
|
|
|
| ACU401
- 03 |
0,37
|
|
|
|
|
| ACU401
- 05 |
0,55
|
|
|
|
|
| ACU401
- 07 |
0,75
|
|
|
|
|
| ACU401
- 09 |
1,1
|
|
|
|
|
| ACU401
- 11 |
1,5
|
|
|
|
|
| ACU401
- 12 |
1,85
|
|
|
|
|
| ACU401
- 13 |
2,2
|
|
|
|
|
| ACU401
- 15 |
3,0
|
|
|
|
|
| ACU401
- 18 |
4,0
|
|
|
|
|
| ACU401
- 19 |
5,5
|
|
|
|
|
| ACU401
- 21 |
7,5
|
|
|
|
|
| ACU401
- 22 |
9,2
|
|
|
|
|
| ACU401
- 23 |
11
|
|
|
|
|
| ACU401
- 25 |
15
|
|
|
|
|
| ACU401
- 27 |
18,5
|
|
|
|
|
| ACU401
- 29 |
22
|
|
|
|
|
| ACU401
- 31 |
30
|
|
|
|
|
| ACU401
- 33 |
37
|
|
|
|
|
| ACU401
- 35 |
45
|
|
|
|
|
| ACU401
- 37 |
55
|
|
|
|
|
| ACU401
- 39 |
65
|
|
|
|
|
| ACU401
- 43 |
75
|
|
|
|
|
| ACU401
- 45 |
90
|
|
|
|
|
| ACU401
- 47 |
110
|
|
|
|
|
| ACU401
- 49 |
132
|
|
|
|
|
|
|
|
| ACU201
- 01 |
0,25
|
|
|
|
|
| ACU201
- 03 |
0,37
|
|
|
|
|
| ACU201
- 05 |
0,55
|
|
|
|
|
| ACU201
- 07 |
0,75
|
|
|
|
|
| ACU201
- 09 |
1,1
|
|
|
|
|
| ACU201
- 11 |
1,5
|
|
|
|
|
| ACU201
- 13 |
2,2
|
|
|
|
|
| ACU201
- 15 |
3,0
|
|
|
|
|
| ACU201
- 18 |
4,0
|
|
|
|
|
| ACU201
- 19 |
5,5
|
|
|
|
|
| ACU201
- 21 |
7,5
|
|
|
|
|
| ACU201
- 22 |
9,2
|
|
|
|
|
*200%
overload - 1sec
150% overload - 1min |
|
|
Power
Range (ACU401)
0.25 - 132 kW / three-phase 360 V - 480 V / 50 Hz - 60
Hz (± 10%)
Power Range (ACU201)
0.25 - 9.2 kW / single or three-phase 200 V - 240 V /
50 Hz - 60 Hz (± 10%)
Type of Control
Selectable Vector control function: sensor-less control,
sensor-less fieldoriented control, field oriented control
with speed sensor,field oriented control of synchronous
servomotors with speed/position sensor
Overload Capacity
150% for 60s / 200% for 1s
Switching Frequency
2, 4, 8, 12, 16 kHz
Enclosure
IP20 (EN 60529)
EMC Filter
Integrated up to 9.2 kW (EN 61800-3)
Main Standard Hardware features
Integrated safe torque off function, External 24Vdc supply
for control boardand electronics, Integrated dynamic braking
module, DC link connectionStandard encoders interface,
Resolver module for feedback acquisitionfrom Bonfiglioli
servomotors, Motor temperature monitoring, Plug-in powerterminals
(up to 3kW), Plug-in and programmable control terminals6
digital input, 1 multifunction input, 1 digital output,
1 multifunctionOutput, 1 relay output (changeover contact)
Optional Expansion Modules
Expansion of analog, digital inputs and outputs, additional
encoder orresolver input, repetition frequency output,
System bus
Optional Communication Modules
RS232, RS485, Modbus, Profibus-DP, CANopen
Optional Keypad
Removable keypad KP500 with copy function,Cabinet mounting
kit and handheld for keypad
PC Software VPlus
Windows-based engineering "workbench" with easy
interface, Driveparameters set-up, Terminal monitor, Actual
value window, Scope function,Bonfiglioli servomotors quick-configuration
window, Motion block parametersmanagement, Teleservice
Main Software Features
32 Programmable Motion blocks, 36 Homing functions according
toCANopen DSP4.02, Unit converter, Jog function, Absolute
and relativepositioning modes, Touch probe, Teach-In functions,
Rotary table control,Programmable reference value channel,
Programmable start and stopcharacteristics, Motor potentiometer,
Programmable S curve, 4 data sets,Auto start-up and commissioning,
Auto reset after failure, Auto start afterpower failure,
PI controller, Programmable logic and timer functions,
Bumpless torque / speed changeover, Master / Slave function
with electronicgear, Index and stability control, Intelligent
current limits, Power failureregulation, Comprehensive
monitoring and protection capabilities, Highspeed control,
Function for lift, crane and winch applications, 3 differentbrake
Management Functions.Advanced application functions: advanced
brake release control, spindlecontrol up to 1000Hz, traverse
function for winders, Volume flow control,load evaluation.
|